If the minimizer exits with ``line search abandoned" and
very large van der Waals energies (in the thousands of
kcal mole ), the
structure probably has bad contacts. The output of
X-PLOR provides a list of bad contacts
.
One should check the molecule and symmetry-related molecules on
the graphics and fix the problem. If this is inconvenient,
try the following procedure:
use the ``repel" nonbonded energy
function (see Section 4.1) for
the first several steps of minimization. One should
replace the minimization statement in the example above
with the following statements:
parameter nbonds repel=0.89 rcon=4. end end {*This turns on the repulsive *} {*function. *} minimize powell nstep=40 drop=40.0 end {* This switches back to the Lennard-Jones function.*} parameter nbonds repel=0.0 end end minimize powell nstep=40 drop=40.0 end
Xplor-NIH 2013-06-06