Syntax
- MINImize RIGId
- { minimize-rigid-statement } END is invoked from the main level of X-PLOR.
- minimize-rigid-statement :==
-
- DROP=real
- designates the expected initial drop in energy (default: 1).
- GROUp=selection
- selects atoms that will be forming a rigid group. Multiple specification of GROUps will define multiple rigid groups. The group selections have to be disjoint (default: one group consisting of all nonfixed atoms). The default is overwritten as soon as a GROUp statement is issued.
- NPRInt=integer
- is the frequency of the energy printout (default: 1).
- NSTEp=integer
- is the maximum number of minimization cycles (default: 50).
- TOLErance=real
- stops minimization if the norm of
the gradient of the energy function is smaller than
the specified number (default: 0.01).