Proton Chemical Shift Restraints
X-PLOR has the facilities to refine against nonexchangable proton chemical shifts. The predicted chemical shift is calculated for each proton as the sum of four terms. The terms are the random coil, ring-current, magnetic anisotropy and electric-field chemical shifts.
The ring-current is calculated as
(24.1) |
The magnetic anisotropy term represents the sum of the anisotropies
arising from the C'-O and C'-N bonds of the backbone and the
side-chain functional groups of Asp, Glu, Asn, and Gln.
(24.2) |
Finally, the electric-field chemical shifts is calculated by
(24.3) |
The potential is calculated as . For more information, see Kuszewski, Gronenborn, and Clore (1995).
For non-stereoassigned protons, there is a method of calculating the potential to account for both possible assignments. For details, see Kuszewski, Gronenborn, and Clore (1996a).
Subsections Xplor-NIH 2024-09-13